What has been tested
In September 2026, samples of our steel wire were tested by GRGTEST (广电计量检测集团股份有限公司), an independent testing group. Four reports were issued. They answer the questions buyers ask most often: what the steel is made of, how strong it is, and whether it contains restricted substances.
Chemical composition
C202613085891
- Carbon
- 0.066 %
- Silicon
- 0.073 %
- Manganese
- 0.294 %
- Phosphorus
- 0.006 %
- Sulphur
- 0.007 %
- Conclusion
- Meets GB/T 700-2006 Q195 requirements for these elements
- Issued
- 17 September 2026
Tensile properties
C202613085892
- Yield Rp0.2
- 857 MPa
- Tensile Rm
- 1,016 MPa
- Elongation A
- 6.0 %
- Method
- GB/T 228.1-2021
- Issued
- 18 September 2026
RoHS restricted substances
C202613085090
- Lead (Pb)
- Not detected (limit 1,000 mg/kg)
- Cadmium (Cd)
- Not detected (limit 100 mg/kg)
- Mercury (Hg)
- Not detected (limit 1,000 mg/kg)
- Cr(VI)
- Not detected
- Directive
- 2011/65/EU Annex II, as amended by (EU) 2015/863
- Conclusion
- Compliant
REACH SVHC screening
C202613085091
- Substances
- 73 substances of very high concern screened
- Result
- All below 0.1 % (w/w)
- Regulation
- (EC) 1907/2006, Article 33
- Conclusion
- Compliant — SVHC ≤ 0.1 % (w/w)
Standards referenced
| Area | Standard or regulation | Used for |
|---|---|---|
| Material | GB/T 700-2006, grade Q195 | Carbon structural steel composition |
| Tensile testing | GB/T 228.1-2021 | Yield strength, tensile strength, elongation |
| Composition methods | SN/T 0750-1999, GB/T 20123-2006 | Element analysis by ICP-OES and carbon/sulphur analyser |
| RoHS | 2011/65/EU Annex II, as amended by (EU) 2015/863 | Lead, cadmium, mercury, hexavalent chromium |
| REACH | (EC) 1907/2006, SVHC list | Screening of 73 substances of very high concern |
Report covers
The first page of each report is shown below; the full PDFs are linked from the cards above.
What these reports are — and are not
The reports describe the samples submitted in September 2026. They are not a certificate covering every order, and they do not replace the specification agreed on a quotation. Where a figure appears on this site — for example Rm 1,016 MPa — it is the value measured on that sample, not a guaranteed range for all production.
If your market needs a specific test, a current report or a declaration in your own format, include the requirement with your inquiry and we will confirm what can be provided.